+86 18126862446
Products

PalmUS
PortableUS
TrolleyUS
VetUS
BladderUS
Ophthalmic
ECG&Monitor
Acc.
SM-12F Multi-parameter monitor
[pics:title]
SM-12F Multi-parameter monitor
[pics:title]

SM-12F Multi-parameter monitor

FeaturesUnique accessory management cabinet12.1 inch high resolution color TFT displayUSB interfaces
Inquire →







Features
Unique accessory management cabinet
12.1 inch high resolution color TFT display
USB interfaces support easy software upgrade and data transfer
Three Working Modes : Monitoring , Surgery and Diagnosis
Simple and friendly operating display interface
Multi-display modes suitable for different applications
Standard Interface , Large font , ECG Standard Full Display ,OXY Trend Table ,BP Trend
Built-in high capacity battery up to 3 hours of continuous work
VGA output for external display
 
Technique Specification
ECG

Lead Mode : 5 Leads ( I , ll , Ill , AVR , AVL , AVF , V )
Gain : 2.5mm / mV, 5.0mm /mV , 10mm /Mv,  20mm /mV
Heart Rate : 15-300 BPM ( Adult ) ; 15-350 BPM ( Neonatal )
Resolution : 1 BPM
Accuracy : ± 1%
Sensitivity > 200 uV ( Peak to peak )
ST measurement range : -2.0 ~+ 2.0 Mv
Accuracy : -0. 8mV~+ 0. 8mV : ± 0. 02mV or ± 10% , which is greater
Other Range : unspecified
Sweep speed : 12.5 mm / s , 25mm / s , 50mm / s
Bandwidth:
Diagnostic : 0.05~130 Hz
Monitor : 0.5~40 Hz
Surgery : 1~20 Hz

SPO2
Measuring Range : 0 ~ 100%
Resolution : 1%
Accuracy : 70%~100% ( ± 2 % )
Pulse Rate : 20-250 BPM
Resolution : 1 BPM
Accuracy : ± 3 BPM
 
Optinal Parameters :
Central monitoring system
Dual IBP
Etco 2
12-lead ECG
Nellcor SpO2
Sun Tech NIBP
 
NIBP
Method : Oscillometry
Measure mode Manual, Auto, STAT
Unit : mmHg , kPa
Measure and alarm range:
Adult Mode
   SYS    40 ~ 280 mmHg
   DIA    10 ~ 225 mmHg
   MEAN  20 ~ 240 mmHg
 
Pediatric Mode
   SYS 40 ~ 220 mmHg
   DIA 10 ~ 160 mmHg
   MEAN 20 ~ 170 mmHg
 
Neonatal Mode
   SYS 40 ~ 135 mmHg
   DIA 10 ~ 100 mmHg
   MEAN 20 ~ 110 mmHg
Resolution : 1 mmHg
Accuracy : ± 5 mmHg
 
TEMP
Measure and Alarm Range : 0 ~ 50 C
Resolution : 0 . 1C
Accuracy : ± 0 . 1C
 
Standard Parameters 
ECG, RESP, TEMP, NIBP, SPO2, PR
 
RESP
Method : Impedance between RA-LL or RALA
Measurement Range:
Adult : 10~120 BrPM
Neonatal / Pediatric : 7~150 BrPM
Resolution : 1 BrPM
Accuracy : ± 2 BrPM

Standard Configuration
No                Item                                         Qty

  1. 1                Main Unit                                     1

  2. 2                5-lead ECG cable                         1

  3. 3                Disposable ECG Electrode           5

  4. 4                Adult Spo2 probe                        1

  5. 5                Adult NIBP cuff                            1

  6. 6                NIBP extension tube                    1

  7. 7                Temperature probe                      1

  8. 8                Power Cable                                 1

  9. 9                User Manual                                 1

  10. 10                Fuse                                             3


Packing
Single package size : 37 *28* 36cm
Single gross weight : 4 KG
6 uniter carton ,package size :58 *39 *75cm , total gross weight 20 KG



Contact

Your Name :*

Tel Number:*

E-mail:

Company Name

Description

ADD:Guangzhou, China.  TEL:+86-20-32382095  PHONE:+86 18126862446  EMAIL:sonostar@sonostar.net  WEBSITE:http://www.sonostarmed.com